| Mullion
Options and Strength - Serviceability Ratings
|
| Mullion
Options and Strength - Serviceability Ratings |
|
|
We have a snap together and an interlock mullion for both
frame sizes. |
|
|
When
the overall width of the framing system exceeds 6000mm
we recommend interlocking mullions to accommodate expansion
and contraction.
|
|
Mullion
|
Mullion
|
102mm
|
102mm
|
150mm
|
150mm
|
|
Height
|
Centres
|
Snap
|
Interlock
|
Snap
|
Interlock
|
|
2400
|
800
|
2388Pa
|
2747Pa
|
3333Pa
|
3333Pa
|
|
2400
|
1000
|
1960Pa
|
2255Pa
|
3333Pa
|
3333Pa
|
|
2400
|
1200
|
1686Pa
|
1940Pa
|
3333Pa
|
3333Pa
|
|
2600
|
800
|
1865Pa
|
2146Pa
|
3333Pa
|
3333Pa
|
|
2600
|
1000
|
1525Pa
|
1755Pa
|
3333Pa
|
3333Pa
|
|
2600
|
1200
|
1306Pa
|
1502Pa
|
3301Pa
|
3333Pa
|
|
2800
|
800
|
1486Pa
|
1709Pa
|
3333Pa
|
3333Pa
|
|
2800
|
1000
|
1211Pa
|
1393Pa
|
3314Pa
|
3333Pa
|
|
2800
|
1200
|
1033Pa
|
1188Pa
|
2816Pa
|
3073Pa
|
|
3000
|
800
|
1203Pa
|
1383Pa
|
3333Pa
|
3333Pa
|
|
3000
|
1000
|
978Pa
|
1125Pa
|
2870Pa
|
3131Pa
|
|
3000
|
1200
|
832Pa
|
957Pa
|
2433Pa
|
2654Pa
|
|
3200
|
800
|
988Pa
|
1136Pa
|
3017Pa
|
3312Pa
|
|
3200
|
1000
|
801Pa
|
922Pa
|
2448Pa
|
2688Pa
|
|
3200
|
1200
|
680Pa
|
782Pa
|
2076Pa
|
2279Pa
|
Ratings over 3333Pa have been displayed as 3333Pa.
Based on 1/250 metal deflection. More span charts are shown in the
AWS Specifier Manual.For CAD files go to installation details.
|