Glass Strength & Safety
There
are two main strength issues to watch on ClearVENT
sashes. The strength of glass supported on two sides and
human impact. Both are covered in Australian Standard
AS1288.
![]()
Glass
Strength Examples:
|
Maximum
ClearVENT Window
Width at:
|
|||
| Glass Type |
700Pa
|
1000Pa
|
1500Pa
|
| 6mm Annealed |
1170mm
|
1001mm
|
844mm
|
| 5mm Toughened |
1187mm
|
1069mm
|
832mm
|
| 6mm Toughened |
1210mm
|
1210mm
|
1122mm
|
| 6.38mm Laminated |
702mm
|
532mm
|
401mm
|
Sound Reduction
ClearVENT
fitted with 6mm gave a sound reduction of 26dB(A) RW26.
Tested at the National Acoustic Laboratories.