SlideMASTER
doors have been tested for compliance with Australian
Standard AS2047.
Strength - Servicability Ratings
Weak Link: Meeting stiles will be the limiting strength factor on tall sliding doors where bottom rails will become the
weak link as the panels get wider.
The tables below show how the strength of doors will change
as the meeting stiles change and doors get wider.
Typical
Door Ratings
Stacking
doors type 'XXF' and 'FXX'
Frame
Frame
Light
Medium
Heavy
Height
Width
Rating
Rating
Rating
2400
2700
1027Pa
3000Pa
3000Pa
2400
3600
791Pa
2412Pa
3000Pa
2400
4500
665Pa
2027Pa
3000Pa
2400
4800
636Pa
1941Pa
2965Pa
2400
5100
613Pa
1870Pa
2468Pa
SlideMASTER Windows: We can also match this sliding
door.